General specifications | |
---|---|
Detection type | magnetic sampling |
Device type | Multiturn absolute encoder |
Linearity error | ± 0.1 ° |
Functional safety related parameters | |
MTTFd | 14.3 a |
L10 | 74 E+8 at 3000rpm and 20/40N axial/radial shaft load |
Electrical specifications | |
Operating voltage | 10 ... 32 V DC |
No-load supply current | max. 120 mA at 10 V DC max. 50 mA at 24 V DC |
Output code | binary code |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) |
Interface | |
Interface type | CANopen |
Resolution | |
Transfer rate | max. 500 kBit/s |
Connection | |
Connector | M12 connector, 5-pin, A-coded for DeviceNet, CANopen |
Standard conformity | |
Degree of protection | DINEN60529, IP66 |
Climatic testing | DIN EN ISO 9227-NSS , salt spray |
Emitted interference | EN 61000-6-4:2007 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 100g, 6ms |
Permanent shock resistance | DIN EN 60069-2-29: ? 10 g, 16 ms |
Vibration resistance | DINEN60068-2-6, 10g, 10...1000Hz |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions | |
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Material | |
Rotational speed | ? 3000 min -1 |
Moment of inertia | 30 gcm2 |
Starting torque | ? 3 Ncm (version without shaft seal) |
Shaft load |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |