General specifications | |
Operating frequency | 13.56 MHz |
Transfer rate | 26 kBit/s |
Sensing range | |
UL File Number | E87056 |
Functional safety related parameters | |
MTTFd | 680 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
LED red/green | Green: power on Flashing green: IO-Link communication Flashing red/green: IO-Link communication interrupted |
LED blue/yellow | Blue: Write/read attempt performed Yellow: Read/write tag detected |
Electrical specifications | |
Rated operating voltage | 20 ... 30 V DC , ripple10%SS |
Power consumption | ? 2 W |
Interface | |
Interface type | IO-Link |
Protocol | IO-Link V1.1 |
Cycle time | min. 4 ms |
Mode | COM3 (230.4 kBaud) |
Process data witdh | 32 Byte |
SIO mode support | no |
Directive conformity | |
Electromagnetic compatibility | |
Radio and telecommunication terminal equipment | |
Standard conformity | |
Degree of protection | EN60529:2000 |
RFID | ISO/IEC 15693-2:2006 ISO/IEC 15693-3:2009 ISO/IEC 18000-3:2010 |
Approvals and certificates | |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
FCC approval | This device complies with pИли отправьте нам запрос наeration is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
IC approval | This device complies with Industry Canada licence-exempt RSS standard(s) and with pИли отправьте нам запрос наeration is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. |
Radio approval | USA: FCC IREIQT1FPIO Canada: 7037A-IQT1FPIO |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Degree of protection | IP67 |
Connection | M12 x 1 connector |
Material | |
Installation | |
Mass | approx. 380 g |